Indicators;CBE Variant;ANT Variant
according to Russian technical standards;2% cement / 3% emulsion / water;2% cement / 0,01% ANT / water
Compressive strength (Rc), MPa, at 7 days curing, at temperatures:
20°С;3,52;4,56
50°С;1,18;1,86
Total water saturation by volume, %;7,3;6,2
Water resistance coefficient (ratio of strength after full water saturation to strength in dry condition);0,86;0,9